E3
Hisense Evaporator Temperature Sensor Failure

Hisense ice maker shows E3 and stops making ice; unit may still power on and circulate water.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted evaporator NTC sensor, Damaged sensor wiring harness, Corroded sensor connector at main PCB, Faulty main control PCB temperature input

How to Fix / Troubleshooting

Safety: Unplug the unit before removing panels or handling wiring.

  • Locate the evaporator sensor: Remove the rear or side panel to access the evaporator plate/coil. The sensor is usually clipped or strapped to the evaporator surface with two wires leading to the control board.
  • Inspect the sensor and wiring: Look for broken insulation, corrosion, or a sensor that has fallen off the evaporator. Reattach it firmly with the original clip or thermal tape.
  • Test the sensor: Disconnect the sensor from the harness and measure its resistance with a multimeter. Compare the reading to the Hisense service chart (typically 5–20 kΩ depending on temperature). If reading is open, shorted, or far out of spec, replace the sensor.
  • Check connector at PCB: Ensure the sensor plug is fully seated on the main control board and pins are not bent or corroded.
  • Replace sensor: If wiring is intact and resistance is incorrect, install a new Hisense evaporator NTC sensor and route the wires away from sharp edges and hot components.
  • Control board check: If a known-good sensor still triggers E3, the temperature input circuit on the main PCB may be defective and the board should be replaced.