E6
hOmeLabs Ambient Temperature Sensor Fault

hOmeLabs ice maker shows E6 and will not start an ice cycle

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective ambient thermistor, Sensor dislodged from mounting point, Broken or pinched sensor wiring, Control board sensor circuit failure

How to Fix / Troubleshooting

Safety: Always unplug the unit before removing panels or handling wiring.

Troubleshooting steps:

  • Check room temperature: Ensure the ice maker is used within the specified ambient range (typically 50–90°F / 10–32°C). Extremely hot or cold rooms can trigger protection errors.
  • Locate ambient sensor: The ambient thermistor is often mounted near the air intake grille or on the control board housing. Look for a small probe with two wires.
  • Inspect mounting: Confirm the sensor is not touching hot components (compressor, condenser) and is exposed to room air.
  • Check wiring: Follow the sensor wires to the control board. Make sure the connector is secure and wires are not damaged.
  • Reset and test: After reseating the connector, reassemble, plug in, and restart. If E6 persists, the sensor or board is likely faulty.

Repair note: Replacing the ambient thermistor is usually straightforward once accessed. If a new sensor does not resolve E6, the main control board will need replacement by a technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ambient Temperature Sensor (Thermistor)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements