Unit powers on but does not start ice making when Start button is pressed
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Unplug before removing the top or front panel.
Troubleshooting:
- Confirm mode and settings: Ensure the unit is not in a cleaning or standby mode. Try switching cube size and then pressing Start again.
- Check for lock function: Some models have a child lock or key combination; verify it is not engaged per the user manual.
- Inspect control panel: Remove the top/front cover to access the control PCB. Check that the ribbon cable to the main board is firmly connected.
- Test button response: With the unit reassembled and powered, press other buttons (size, power) to see if they respond. If only Start fails, the switch on the UI board may be defective.
Repair: Replacing the user interface board or membrane switch assembly is usually required if buttons do not register. If no buttons work, suspect the main control board or power to the UI.
Repair Difficulty
Required Part
We may earn a commission from links on this page.