Possible Causes

Failed display board,Loose low‑voltage connector from main PCB,Blown low‑voltage fuse on control board,Cracked display PCB tracks

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing the control area.

  • Check UI cable: Reseat the ribbon cable or harness between the main control PCB and the display board.
  • Inspect for damage: Look for burn marks or cracked solder joints on the display PCB. Replace the board if damaged.
  • Test low‑voltage output: With caution and the unit powered, measure the DC voltage from the main board to the display. If missing, the main PCB may have a blown regulator or fuse and should be replaced.