Possible Causes

Clogged internal drain hole,Blocked or kinked drain hose,Failed drain pump on pumped models,Ice buildup around drain outlet

How to Fix / Troubleshooting

Safety: Disconnect power before clearing drains.

  • Clear drain hole: Locate the internal drain at the bottom of the ice bin or cabinet. Use a soft brush or pipe cleaner to remove debris and scale.
  • Flush with warm water: Pour warm (not boiling) water into the drain to melt ice and flush out blockages.
  • Inspect drain hose: Check the hose routing for kinks or sags that can trap water. Straighten or reroute as needed.
  • Test drain pump: On pumped‑drain Hoover models, verify the pump runs and discharges water. Replace the pump if it hums but does not move water.