6 beeps (repeating)
Hoshizaki Low Voltage or Power Supply Fault

Unit shuts down; control board beeps six times repeatedly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Supply voltage below specification, Loose neutral or ground connection, Failing internal transformer or power supply on control board, Oversized load on shared electrical circuit

How to Fix / Troubleshooting

Safety First: Only qualified persons should measure live voltage. Disconnect power before tightening connections.

  • Measure line voltage: With a multimeter and panels closed, measure voltage at the receptacle and compare to the unit’s nameplate. Voltage should be within ±10% of rating.
  • Check dedicated circuit: Ensure the ice maker is on a dedicated circuit of the correct amperage. Remove other heavy loads (microwaves, heaters) from the same circuit.
  • Inspect internal connections: Disconnect power. Open the electrical compartment and check all wire nuts, terminal screws, and ground connections for tightness and signs of overheating.
  • Check for undersized wiring or long runs: Excessive voltage drop can occur on long or undersized circuits. If voltage at the unit is low but normal at the panel, consult an electrician.
  • Reset and monitor: After corrections, restore power and see if the 6-beep code clears. If low voltage persists, do not continue operating the unit.

When to call a technician: Persistent low-voltage faults after electrical corrections may indicate a failing internal transformer or control board power supply.