E1
Hoshizaki
Evaporator Thermistor Error
Digital display shows E1 and ice production stops
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted evaporator thermistor, Corroded thermistor connector at control board, Thermistor out of calibration, Damaged thermistor wiring harness
How to Fix / Troubleshooting
Safety First: Disconnect power before accessing the control compartment.
- Locate evaporator thermistor: Find the small sensor clipped to the evaporator plate or suction line. Follow its wires back to the control board.
- Inspect wiring and connector: Check for broken insulation, pinched wires, or loose connectors. Reseat the connector on the control board.
- Measure resistance: With the thermistor disconnected and at room temperature, measure resistance with a multimeter. Compare to the Hoshizaki thermistor chart. Replace if open, shorted, or far out of spec.
- Check for moisture intrusion: Moisture in the connector can cause false readings. Dry and clean the connector if needed.
- Reset unit: After replacing or reseating the thermistor, restore power and clear the error by cycling power or pressing reset (per model instructions).
When to call a technician: If a new thermistor does not clear E1, the control board’s sensor circuit may be defective.