E7
Hoshizaki
Water Supply or Fill Error
Digital display shows E7; unit may run briefly then shut down
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Closed or partially closed water shutoff valve, Clogged external water filter, Clogged inlet valve screen, Failed water inlet valve coil
How to Fix / Troubleshooting
Safety First: Disconnect power and close the water supply valve before removing hoses.
- Verify water supply: Confirm the building water supply is on and that the shutoff valve to the ice maker is fully open.
- Replace or bypass water filter: If a filter is installed and older than recommended, replace it or temporarily bypass to test flow.
- Clean inlet screen: Disconnect the inlet line at the water valve and remove any debris from the valve screen.
- Test inlet valve coil: With power off, measure coil resistance and compare to spec. Replace the valve if open or shorted.
- Reset and test fill: Restore power and observe the fill cycle. Ensure the reservoir fills to the proper level within the allowed time.
When to call a technician: If E7 persists with good water pressure and a new valve, the control board or float switch logic may be at fault.