Possible Causes
How to Fix / Troubleshooting
Safety first: Unplug the unit and close the water supply before disconnecting any lines.
Step-by-step checks:
- 1. Confirm power and mode: Ensure the unit is switched on, not in standby, and any "Clean" or "Pause" modes are not active.
- 2. Verify water supply: Check that the shutoff valve is open and the supply line is not kinked.
- 3. Inspect inlet screen: Clean the water inlet valve screen of sediment.
- 4. Run a test cycle: After restoring power and water, listen for the valve filling the reservoir and the circulation pump starting. If there is no fill sound, suspect the inlet valve or control board.
- 5. Replace inlet valve: If water supply is good but the valve never opens, replace the water inlet valve. If the valve is new and still does not energize, the main control PCB may be faulty.
When to call a technician: If both water and power are confirmed and there is still no activity, a technician should test control outputs and sensors.