IceKing No Ice Production Without Error Indication

IceKing ice maker runs but makes no ice at all (no error code displayed).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Water supply turned off, Clogged water inlet filter screen, Failed water inlet valve, Faulty ice-making control logic on main PCB

How to Fix / Troubleshooting

Safety first: Unplug the unit and close the water supply before disconnecting any lines.

Step-by-step checks:

  • 1. Confirm power and mode: Ensure the unit is switched on, not in standby, and any "Clean" or "Pause" modes are not active.
  • 2. Verify water supply: Check that the shutoff valve is open and the supply line is not kinked.
  • 3. Inspect inlet screen: Clean the water inlet valve screen of sediment.
  • 4. Run a test cycle: After restoring power and water, listen for the valve filling the reservoir and the circulation pump starting. If there is no fill sound, suspect the inlet valve or control board.
  • 5. Replace inlet valve: If water supply is good but the valve never opens, replace the water inlet valve. If the valve is new and still does not energize, the main control PCB may be faulty.

When to call a technician: If both water and power are confirmed and there is still no activity, a technician should test control outputs and sensors.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Inlet Valve
Check Price on Amazon