E13
Iceman Cabinet / Ambient Temperature Sensor Fault

E13 displayed, unit beeps and shuts down shortly after start, internal temperature reading is incorrect

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted cabinet thermistor, Disconnected sensor harness, Sensor out of position, Failed main PCB sensor circuit

How to Fix / Troubleshooting

Safety: Disconnect power before accessing internal wiring.

  • 1. Locate ambient sensor: The cabinet or ambient thermistor is usually mounted near the air intake or inside wall of the ice bin area. Refer to the Iceman service diagram.
  • 2. Inspect mounting: Ensure the sensor is properly clipped in place and not dangling or touching hot components.
  • 3. Check wiring: Follow the sensor leads to the control board. Reseat connectors and look for damaged insulation.
  • 4. Measure resistance: At room temperature, measure the thermistor resistance and compare to the Iceman spec chart. Replace the sensor if readings are far off or show open/short.
  • 5. Control board evaluation: If a known-good sensor still results in E13, the sensor input circuit on the main PCB may be defective. Replace the main PCB.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet Thermistor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements