E20
Ikea General Temperature Sensor / Thermistor Error

E20 error, sensor fault, unit may not start ice cycle

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted cabinet thermistor, damaged sensor harness, incorrect sensor installation, control board ADC failure

How to Fix / Troubleshooting

Safety first: Unplug the ice maker before accessing sensors or the control board.

  • Identify sensors: Ikea ice makers typically have at least one cabinet thermistor and one evaporator thermistor. Refer to the service diagram if available.
  • Inspect harness: Follow the sensor wires from the cabinet to the control board. Check for pinched or cut wires and secure all connectors.
  • Test thermistors: Remove the suspect thermistor and measure resistance at room temperature. Compare to expected values (often 10 kΩ at 25°C). Replace any sensor with readings far outside specification.
  • Control board: If all sensors test correctly but E20 remains, the main control board’s sensor input circuit may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cabinet Thermistor
Check Price on Amazon

We may earn a commission from links on this page.