E8
Kismile
Water Pump Failure or Pump Circuit Error
E8 displayed; water pump may not run, or reservoir does not circulate water to the evaporator.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed circulation pump motor, Blocked pump inlet screen, Airlock in pump, Loose or damaged pump wiring
How to Fix / Troubleshooting
Safety: Unplug the ice maker and drain water before removing the pump.
- Check water level: Ensure the reservoir is filled to the correct level. Low water can cause the pump to suck air and trigger an error.
- Listen for pump: When the unit starts a cycle (with power on), listen for a humming or water flow sound. If silent, suspect a failed pump or power issue.
- Clean pump inlet: Remove the ice basket and access the pump at the bottom of the reservoir. Clean any debris or scale from the pump inlet screen.
- Bleed air: Tilt the unit slightly forward and backward (with water in the reservoir) to help remove trapped air from the pump.
- Inspect wiring: With power off, check the pump’s two-wire connector and harness for damage. Reseat the connector at both the pump and control board.
- Replace pump: If the pump does not run when powered and wiring is intact, replace the water circulation pump with a Kismile-compatible unit, ensuring all hoses are reconnected securely to prevent leaks.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Water Circulation Pump
Check Price on Amazon
We may earn a commission from links on this page.