F1
Kismile
Fan Motor Fault / Fan Speed Error
F1 error; ice maker may stop mid-cycle and not resume until reset.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Obstructed condenser fan blade, Failed fan motor, Loose fan connector, Fan speed feedback signal error on control board
How to Fix / Troubleshooting
Safety: Unplug the ice maker before accessing the fan.
- Inspect fan area: Remove the rear panel and check for dust, plastic wrap, or wires obstructing the fan blade. Remove any obstructions.
- Spin test: Rotate the fan blade by hand. If it feels stiff or grinds, the motor bearings may be failing and the motor should be replaced.
- Check wiring: Ensure the fan motor connector is fully seated on the control board and that wires are not damaged.
- Test operation: Restore power and observe whether the fan starts when the compressor runs. If not, replace the fan motor.
- Control board check: If a new fan does not run and F1 persists, the control board’s fan driver circuit may be defective and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.