ADD
Klarstein Water Refill Reminder / Low Water Detection

Display shows ADD or ADD WATER; unit beeps and will not start ice cycle.

Advertisements

Possible Causes

Low water level in tank, Sensor fouled by scale or slime, Loose sensor connector on PCB

How to Fix / Troubleshooting

Safety first: Unplug the ice maker before cleaning the reservoir.

  • Fill tank: Add water to the reservoir up to the indicated MAX line.
  • Clean sensor area: If the ADD message remains, clean the float or probes with a soft brush and mild detergent, then rinse thoroughly.
  • Check wiring: Access the base of the unit and trace the sensor wires to the control board. Ensure the connector is fully seated.
  • Reset: Plug the unit back in and press the power/start button to clear the ADD message.

If the ADD warning persists with a full tank and clean sensor, replace the water level sensor assembly.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Level Sensor / Float Switch
Check Price on Amazon