E6
Klarstein Main PCB Communication / Internal Control Error

Display shows E6; unit may not start ice-making cycle at all.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty main control board, Loose display-to-PCB ribbon cable, Power surge damage, Corrupted firmware (rare)

How to Fix / Troubleshooting

Safety first: Unplug the Klarstein ice maker before opening the control panel.

  • Hard reset: Disconnect the unit from power for at least 10 minutes to discharge internal capacitors. Reconnect and test.
  • Check power source: Plug the ice maker directly into a wall outlet (no extension cord or power strip). Verify correct voltage with another appliance.
  • Inspect control connections: Remove the top/control panel cover and check the ribbon cable between the display board and main PCB. Reseat all connectors firmly.
  • Look for burn marks: Visually inspect the PCB for burnt components or swollen capacitors. If present, the board must be replaced.

If E6 persists after reseating cables and resetting, the main control board is likely defective and should be replaced as a complete module.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.