Possible Causes
Faulty temperature sensor, Overheating due to poor ventilation, Weak compressor start relay, Control board malfunction
How to Fix / Troubleshooting
Safety first: Unplug the unit before inspection.
- Improve airflow: Ensure adequate clearance and clean the condenser coil.
- Check fan: Confirm the condenser fan runs whenever the compressor is on. Replace if intermittent.
- Inspect start relay: Examine the compressor start relay for signs of overheating or rattling. Replace if suspect.
- Monitor behavior: After these steps, observe whether cycle times normalize (several minutes on, several minutes off).
Persistent short cycling can damage the compressor and should be addressed by a technician if basic causes are ruled out.