E11
Koldfront Door / Lid Switch Fault

Unit shows E11 and will not start an ice-making cycle.

Advertisements

Possible Causes

Failed door switch, misaligned door actuator, broken switch wiring, control board not detecting closed door

How to Fix / Troubleshooting

Safety First: Unplug the ice maker before accessing the switch.

Steps to resolve E11:

  • Check door closure: Ensure the door or lid closes fully and that nothing is obstructing it.
  • Locate switch: Find the door or lid switch, usually mounted in the frame or under the top panel where the door contacts.
  • Inspect actuator: Verify the door tab or actuator properly engages the switch when closed. Adjust the door or actuator if misaligned.
  • Test switch: Disconnect the switch and test for continuity with a multimeter. It should show continuity when pressed (door closed) and open when released.
  • Replace switch: If defective, remove mounting screws, disconnect wiring, and install a new Koldfront-compatible door switch. Reconnect wires and secure in place.
  • Test: Restore power and confirm the unit starts a cycle when the door is closed and that E11 is cleared.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon