E15
Koldfront Water Level Sensor / Float Switch Fault

Display shows E15; unit may overfill or not fill correctly with water.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck water level float, failed float switch, mineral buildup on float mechanism, damaged float switch wiring

How to Fix / Troubleshooting

Safety First: Unplug the unit and turn off the water supply.

Steps to resolve E15:

  • Locate float assembly: Access the water reservoir area and find the float or water level sensor assembly.
  • Inspect for obstructions: Check if the float moves freely up and down. Remove any debris, scale, or ice that may be jamming it.
  • Clean float: Use warm water and vinegar to clean mineral deposits from the float and guide tube.
  • Test switch: Disconnect the float switch and test for continuity while moving the float. Replace if readings do not change as expected.
  • Replace float switch: Install a new Koldfront-compatible water level/float switch if defective, reconnect wiring, and ensure proper movement.
  • Test fill: Restore water and power, then run a cycle to confirm proper filling and that E15 is cleared.