E4
Koldfront Evaporator Temperature Sensor / Thermistor Fault

Display shows E4 and the unit shuts down shortly after starting a cycle.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed evaporator thermistor, thermistor dislodged from evaporator plate, damaged thermistor wiring, faulty control board sensor circuit

How to Fix / Troubleshooting

Safety First: Unplug the ice maker before removing any internal covers.

Steps to resolve E4:

  • Access evaporator area: Remove the front or top inner cover to expose the evaporator plate and attached sensor (thermistor).
  • Check sensor placement: Ensure the thermistor is firmly clipped or taped to the evaporator surface where the factory placed it. Reattach if it has fallen off.
  • Inspect wiring: Follow the thermistor wires back to the control board, checking for cuts, abrasions, or loose connectors. Reseat the plug on the board.
  • Measure resistance: Disconnect the thermistor and measure its resistance at room temperature. Compare to the service chart; if it reads open or shorted, it is defective.
  • Replace thermistor: Remove the old evaporator thermistor, install the new Koldfront-compatible sensor in the same location, and secure it firmly to the evaporator surface.
  • Reassemble and test: Reinstall covers, restore power, and run a cycle to verify that E4 does not return.

Tip: If the thermistor tests good but E4 persists, the main control board may need replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Thermistor
Check Price on Amazon

We may earn a commission from links on this page.