Liebherr
Dry Ice Mold / No Fill
Liebherr ice maker cycles but ejector fingers are bare; no water in mold
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Water supply turned off, Kinked or disconnected water line, Failed water inlet valve coil, Control not energizing valve
How to Fix / Troubleshooting
Safety first: Turn off power and water before handling water connections.
- Verify water supply: Confirm the shutoff valve is open and other fixtures on the same line have water.
- Inspect water line: Check behind the appliance for kinks or disconnections. Reconnect and secure as needed.
- Test valve coil (advanced): With power off, measure coil resistance with a multimeter. An open coil indicates a failed valve that must be replaced.
- Control check: If the valve and supply are good but the mold remains dry, the control may not be sending power to the valve; professional diagnosis is recommended.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Liebherr Water Inlet Valve
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements