Liebherr Insufficient Water Fill to Ice Maker

Liebherr ice maker makes ice but cubes are very small or hollow

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially clogged water inlet valve screen, Restricted water line to Liebherr unit, Clogged water filter, Low household water pressure

How to Fix / Troubleshooting

Safety first: Turn off water supply and unplug the appliance before disconnecting any water fittings.

  • Replace water filter: Install a new Liebherr filter if it is near or past its service life.
  • Inspect water line: Check for kinks or crushed sections in the supply line. Replace if damaged.
  • Clean inlet screen: Disconnect the line at the inlet valve and rinse the small mesh screen to remove sediment.
  • Check pressure: Ensure household water pressure is adequate. If not, have a plumber correct the issue.
  • Monitor new cubes: After adjustments, discard the next 1–2 batches of ice and check if cube size normalizes. If not, the inlet valve may be weak and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Liebherr Water Inlet Valve
Check Price on Amazon