E17
Magic Chef Low Water Flow or Restricted Inlet Fault

E17 appears; unit may run but produce very small or hollow ice cubes.

Advertisements

Possible Causes

Partially clogged inlet valve screen, Scale buildup in water line, Partially closed shutoff valve, Failing water inlet valve

How to Fix / Troubleshooting

Safety first: Turn off water supply and unplug the unit before disconnecting hoses.

  • Verify valve position: Confirm the household shutoff valve feeding the ice maker is fully open.
  • Clean inlet screen: Disconnect the water line at the back of the unit and remove the small mesh screen in the inlet valve. Rinse thoroughly to remove sediment.
  • Flush supply line: Briefly run water from the supply line into a bucket to clear debris.
  • Evaluate inlet valve: If water flow remains weak and E17 persists, the internal valve may be restricted or failing. Replace the water inlet valve with a compatible Magic Chef part.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Inlet Valve
Check Price on Amazon

We may earn a commission from links on this page.