E17
Magic Chef
Low Water Flow or Restricted Inlet Fault
E17 appears; unit may run but produce very small or hollow ice cubes.
Advertisements
Possible Causes
Partially clogged inlet valve screen, Scale buildup in water line, Partially closed shutoff valve, Failing water inlet valve
How to Fix / Troubleshooting
Safety first: Turn off water supply and unplug the unit before disconnecting hoses.
- Verify valve position: Confirm the household shutoff valve feeding the ice maker is fully open.
- Clean inlet screen: Disconnect the water line at the back of the unit and remove the small mesh screen in the inlet valve. Rinse thoroughly to remove sediment.
- Flush supply line: Briefly run water from the supply line into a bucket to clear debris.
- Evaluate inlet valve: If water flow remains weak and E17 persists, the internal valve may be restricted or failing. Replace the water inlet valve with a compatible Magic Chef part.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Water Inlet Valve
Check Price on Amazon