E08
Manitowoc Freeze Time Exceeded / Slow Freeze

E08 appears and machine stops; often associated with long freeze or harvest times.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty evaporator plate, Low refrigerant charge, Weak compressor, Poor water flow across evaporator, Scaled water distribution tube

How to Fix / Troubleshooting

Safety first: Disconnect power and shut off water before cleaning. Wear gloves and eye protection when using chemical cleaners.

Steps:

  • Clean evaporator: Remove front panel. Use Manitowoc‑approved ice machine cleaner to descale the evaporator plate/grid thoroughly. Follow with a sanitize cycle.
  • Inspect water distribution: Remove and clean the water distribution tube or spray bar. Ensure all holes are clear so water flows evenly over the evaporator.
  • Check water filter: Replace the external water filter cartridge if flow is reduced. Verify water supply valve is fully open.
  • Verify condenser cleanliness: Clean the condenser coil and ensure the condenser fan is operating properly to maintain correct head pressure.
  • Reset and test: Restore power, clear the error if needed, and run a full cycle. Observe freeze time. If it remains excessively long, a sealed system issue (low charge, restriction, weak compressor) may exist.

When to call a technician: If cleaning and water flow corrections do not resolve E08, have a Manitowoc‑qualified technician check refrigeration pressures and system performance.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Evaporator Plate
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements