E17
Manitowoc Curtain / Door Switch Fault

E17 displayed, unit may not sense door or curtain position correctly, causing cycle faults.

Advertisements

Possible Causes

Sticking or broken water curtain, Failed curtain switch or magnet, Misaligned bin door switch, Damaged switch wiring

How to Fix / Troubleshooting

Safety first: Disconnect power. Be cautious of falling ice when working around the curtain or door.

Steps:

  • Inspect water curtain: On Manitowoc models with a water curtain, ensure it swings freely and is not obstructed by ice buildup or bin contents.
  • Check switch operation: Locate the curtain or door switch (mechanical or magnetic). Manually operate the curtain/door and listen for a click or use a meter to verify switch closure.
  • Clean and realign: Remove any scale or debris from the curtain hinges. Adjust the switch or magnet so that it actuates reliably when the curtain/door moves.
  • Inspect wiring: Check the harness from the switch to the control board for damage and reseat connectors.

Repair: Replace the curtain / bin door switch or the curtain assembly if broken or warped.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Curtain / Bin Door Switch