E15
Marvel
Power Supply / Voltage Fault
Display shows E15; unit may shut down and not restart until power is cycled.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Low or high line voltage, failing internal power supply on control board, loose power connections, tripped internal fuse
How to Fix / Troubleshooting
Safety: Always disconnect power before opening any electrical compartment.
Steps:
- Verify that the outlet supplying the Marvel ice maker has correct voltage using a multimeter (typically 120 VAC in North America). Correct any household wiring issues.
- Ensure the unit is on a dedicated circuit and not sharing power with heavy loads that could cause voltage drops.
- Remove the control board cover and inspect for an internal fuse. Test the fuse for continuity and replace with the exact type and rating if blown.
- Check all line and neutral connections at the terminal block for tightness and signs of overheating.
- If voltage to the board is correct but the unit intermittently shuts down with E15, the board’s internal power supply may be failing. Replace the main control board.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.