E17
Maytag
Overtemperature Protection
Ice maker displays high ambient temperature error, production slows or stops
Advertisements
Possible Causes
Room temperature above design limit, condenser coil clogged, condenser fan not running, unit installed in confined space
How to Fix / Troubleshooting
Safety first: Disconnect power before cleaning coils or accessing fans.
- Measure room temperature: Confirm the ambient temperature. If above 100°F, improve ventilation or relocate the unit.
- Clean condenser: Remove access panel and vacuum dust from the condenser coil. Use a coil brush to reach between fins.
- Check condenser fan: Verify the fan spins freely and runs when the compressor is on. Replace the fan motor if it fails to start.
- Improve airflow: Ensure the ice maker has the clearances specified by Maytag on all sides and above. Do not enclose it tightly in cabinetry without proper ventilation.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condenser Fan Motor