E17
Maytag Overtemperature Protection

Ice maker displays high ambient temperature error, production slows or stops

Advertisements

Possible Causes

Room temperature above design limit, condenser coil clogged, condenser fan not running, unit installed in confined space

How to Fix / Troubleshooting

Safety first: Disconnect power before cleaning coils or accessing fans.

  • Measure room temperature: Confirm the ambient temperature. If above 100°F, improve ventilation or relocate the unit.
  • Clean condenser: Remove access panel and vacuum dust from the condenser coil. Use a coil brush to reach between fins.
  • Check condenser fan: Verify the fan spins freely and runs when the compressor is on. Replace the fan motor if it fails to start.
  • Improve airflow: Ensure the ice maker has the clearances specified by Maytag on all sides and above. Do not enclose it tightly in cabinetry without proper ventilation.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condenser Fan Motor
Check Price on Amazon