E19
Maytag Circulation Pump Failure

Ice maker indicates pump error, no water circulation over evaporator

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed circulation pump motor, clogged pump inlet, airlock in pump, wiring issue to pump

How to Fix / Troubleshooting

Safety first: Disconnect power and shut off water before servicing the pump.

  • Access pump: Remove the front panel and ice bin. Locate the circulation pump in the reservoir area.
  • Inspect for debris: Remove the pump cover or inlet screen and clear any debris or scale buildup.
  • Bleed air: Refill the reservoir and tilt the unit slightly if needed to help purge air from the pump.
  • Test pump: With the pump disconnected, measure motor resistance. If open, replace the pump. Briefly apply power (following safety procedures) to confirm operation.
  • Check wiring: Ensure the pump harness is secure and not damaged.
  • Replace pump: Install a new OEM Maytag circulation pump if defective, ensuring all seals and gaskets are properly seated to prevent leaks.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Circulation Pump
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements