E1
Midea Cabinet Temperature Sensor (Thermistor) Failure

Ice maker stops and displays E1; unit may beep and compressor does not start

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted evaporator thermistor, Damaged thermistor wiring harness, Corroded thermistor connector on main PCB, Failed main control board sensor circuit

How to Fix / Troubleshooting

Safety first: Unplug the ice maker from the wall outlet before opening any panels. Do not work on the unit while it is connected to power.

  • Power reset: Unplug the unit for 5–10 minutes, then plug it back in and see if E1 clears. If it returns, continue.
  • Access the thermistor: Remove the rear or side service panel (varies by Midea model). Locate the small, usually white or black, bullet-style sensor clipped to the evaporator plate or near the ice-making area. It will be connected by two thin wires to the main PCB.
  • Inspect wiring: Check the thermistor wires for cuts, pinches, or burn marks. Ensure the connector is fully seated on the main control board. Reseat the connector several times to clean contacts.
  • Check sensor resistance (for advanced DIYers): With the unit unplugged, disconnect the thermistor from the board and measure resistance with a multimeter. At room temperature (around 25°C / 77°F), most Midea NTC thermistors will read between 5–20 kΩ. A reading of 0 Ω (short) or OL (open) indicates a bad sensor.
  • Replace if faulty: If the thermistor is open/shorted or physically damaged, replace it with a compatible Midea evaporator/temperature sensor. Route the new sensor along the original path and secure it with clips or zip ties away from moving parts.
  • If sensor tests good: The fault may be on the main PCB. Inspect the board for burnt components. If no obvious damage is visible but E1 persists, the main control board likely needs replacement and is best handled by a qualified technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Thermistor
Check Price on Amazon

We may earn a commission from links on this page.