E10
Monogram
Water Flow / Circulation Fault
E10 displayed; ice maker may run but produce very small or hollow cubes/nuggets.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Clogged water distribution tube, scaled circulation pump, weak circulation pump motor, mineral buildup in water system
How to Fix / Troubleshooting
Safety First: Disconnect power and water before disassembling water system components. Use only manufacturer-approved cleaners.
- Run cleaning cycle: Follow the Monogram manual to run a full descaling/cleaning cycle using approved ice machine cleaner. This can restore proper water flow.
- Inspect distribution tube: Access the evaporator area and check the water distribution tube or spray bar for clogged holes. Clean with a soft brush and soak in cleaner if heavily scaled.
- Check circulation pump: Locate the water circulation pump in the sump. Inspect for debris around the impeller and clean as needed.
- Test pump operation: With power restored, observe water flow over the evaporator during a freeze cycle. Weak or no flow indicates a failing pump that should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Water Circulation Pump
Check Price on Amazon