E3
Monogram Evaporator Temperature / Freeze Time Fault

Unit displays E3 and shuts down or fails to complete ice harvest cycle.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge, restricted capillary tube, dirty condenser coil, failed evaporator thermistor, weak compressor

How to Fix / Troubleshooting

Safety First: Disconnect power before removing panels. Refrigeration system work involves high pressure and should be done by a licensed technician.

  • Clean condenser: Remove the lower front grille and use a soft brush and vacuum to clean dust and lint from the condenser coil. A dirty condenser can cause improper freeze times.
  • Check airflow: Ensure the unit has proper clearance around the front and sides as specified in the Monogram installation guide. Poor ventilation can cause high operating temperatures.
  • Inspect evaporator frost pattern: With power restored and panels removed, observe the evaporator during a freeze cycle (only if you are comfortable and safe doing so). An uneven frost pattern may indicate a sealed system issue.
  • Verify thermistor connections: Check the evaporator thermistor wiring and connector at the control board.
  • Call a professional: If cleaning and basic checks do not clear E3, a sealed system or compressor issue is likely. Contact a qualified Monogram service technician for refrigerant and compressor diagnostics.