Short Cycling
Unit cycles on and off rapidly, never staying on long enough to make ice.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Overheating compressor, faulty overload protector, control board relay chatter, poor ventilation
How to Fix / Troubleshooting
Safety First: Disconnect power before accessing compressor or control board.
- Improve airflow: Ensure the condenser coil is clean and the front grille is unobstructed.
- Check ambient temperature: Very high room temperatures can cause thermal overload. Improve room cooling or ventilation.
- Inspect overload: Replace a suspect compressor overload protector if it is repeatedly tripping.
- Control board: If short cycling persists with good airflow and a new overload, the main control board may have a faulty relay and should be replaced.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Compressor Overload Protector