E8
Northair
Drain Pump or Drain Valve Fault
Display shows E8; unit may fill with water but then drains immediately or will not hold water in the reservoir.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck-open drain valve, Shorted drain pump running continuously, Faulty drain pump relay on control board, Miswired drain pump harness
How to Fix / Troubleshooting
Safety: Disconnect power and close any external drain valves before working on the drain system.
Steps:
- Observe behavior: If water drains out as soon as it fills, listen for the drain pump running constantly.
- Access drain pump/valve: Remove the lower rear or side panel to locate the drain pump or solenoid valve connected to the drain hose.
- Check for debris: Inspect the drain line and pump inlet for obstructions that might hold the valve partially open. Clean as needed.
- Electrical test: With the unit unplugged, disconnect the pump and measure coil resistance. If the pump is shorted or open, replace it. Also check for signs of overheating or melted plastic.
- Control board check: If the pump tests good but runs whenever the unit is powered, the control board relay may be stuck closed. Inspect the board and replace if necessary.
- Reassemble and test: Reconnect hoses securely, restore power, and run a cycle to confirm proper fill and drain operation.
Warning: Ensure the drain hose is routed correctly and not below the water level in a way that could cause siphoning.
Advertisements
Repair Difficulty
Medium
3/5