E1
OBH Nordica
Evaporator Temperature Sensor Failure
Ice maker stops shortly after startup and displays E1 on the control panel.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective NTC temperature sensor on evaporator, Broken or loose sensor wiring harness, Corroded sensor connector on main PCB, Failed main control PCB temperature input circuit
How to Fix / Troubleshooting
Safety first: Unplug the OBH Nordica ice maker from the mains before opening any panels. Never work on the unit while it is connected to power.
Step-by-step checks:
- Power-cycle the unit: Unplug for 10 minutes, then plug back in and restart. If E1 returns immediately, continue.
- Access the evaporator sensor: Remove the rear or side service panel (depending on model). Locate the small NTC sensor clipped or strapped to the evaporator plate or tubing, usually with two thin wires going to the main PCB.
- Inspect wiring and connector: Check for pinched, cut, or broken wires between the sensor and the control board. Reseat the connector on the PCB and at the sensor (if removable). Look for corrosion or moisture on the contacts and dry gently if needed.
- Check sensor mounting: Ensure the sensor is firmly attached to the evaporator surface; a loose sensor can read incorrect temperatures and trigger E1. Re-clip or re-tape it securely.
- Test or replace the sensor: If you have a multimeter, measure the sensor resistance at room temperature and compare with the service chart (typical NTC values are around 5–20 kΩ at 25°C). If readings are open, shorted, or far off spec, replace the evaporator temperature sensor with an OBH Nordica-compatible part.
- If E1 persists: After replacing the sensor and confirming wiring, the fault may be on the main control PCB. At this point, contact an authorized OBH Nordica service center for PCB diagnosis or replacement.