Pro Breeze
False Ice Bin Full Detection
Ice maker stops making ice even though the bin is not full; restarting resumes production temporarily.
Advertisements
Possible Causes
Dirty or misaligned ice full sensor, Ice bridging near sensor, Weak infrared emitter, Faulty sensor wiring
How to Fix / Troubleshooting
Safety first: Disconnect power before cleaning or adjusting sensors.
- Step 1 – Clean sensor lenses: Wipe the ice full sensor windows with a soft, damp cloth.
- Step 2 – Break ice bridges: Ensure ice is not forming a solid bridge near the sensor. Empty the bin and allow new ice to form.
- Step 3 – Check alignment and mounting: Confirm both sides of the sensor pair are firmly mounted and facing each other.
- Step 4 – Replace sensor assembly: If the problem recurs frequently, replace the ice full sensor assembly.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ice Full Sensor Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements