RCA Poor Ice Production / Incomplete Freezing

RCA ice maker makes ice very slowly; ice cubes are small or hollow.

Advertisements

Possible Causes

High ambient temperature, Dirty condenser coil, Low water level or restricted water flow, Weak compressor or low refrigerant

How to Fix / Troubleshooting

Safety first: Unplug the unit before cleaning internal components.

  • Step 1 – Improve environment: Move the ice maker away from heat sources and ensure room temperature is within the recommended range.
  • Step 2 – Clean condenser: Vacuum and brush the condenser coil to improve heat dissipation.
  • Step 3 – Check water supply: Fill the reservoir with cool, clean water. Clean the reservoir and water filter screen to ensure good flow.
  • Step 4 – Descale: Run a cleaning cycle with a manufacturer-approved descaling solution or a mixture of white vinegar and water to remove mineral buildup on the evaporator and water lines. Rinse thoroughly afterward.
  • Step 5 – Evaluate performance: If ice remains small and production is very slow after cleaning and environmental corrections, the compressor or sealed system may be weakening and require professional evaluation.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condenser Coil
Check Price on Amazon

We may earn a commission from links on this page.