High Mineral Content / Aerated Ice
RCA ice maker produces cloudy or white ice cubes.
Advertisements
Possible Causes
Hard tap water, Mineral scale on evaporator, Insufficient flushing after cleaning solution use
How to Fix / Troubleshooting
Safety first: Unplug the unit before descaling.
- Step 1 – Change water source: Use filtered or bottled water with lower mineral content.
- Step 2 – Descale evaporator: Run a descaling cycle with white vinegar and water or a manufacturer-approved cleaner to remove mineral deposits from the evaporator plate.
- Step 3 – Rinse thoroughly: Flush the system with multiple reservoirs of clean water, discarding all ice until the vinegar or cleaner smell is gone.
- Step 4 – Regular maintenance: Repeat cleaning every 1–3 months depending on water hardness.
Advertisements
Repair Difficulty
Very Easy
1/5
Required Part
Evaporator Plate
Check Price on Amazon