E2
Salter
Ice Full Sensor / Infrared Beam Fault
Display shows E2 and machine stops mid-cycle, ice production halts
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked ice full sensor, Misaligned infrared emitter/receiver, Faulty ice full sensor board, Loose sensor wiring harness
How to Fix / Troubleshooting
Safety: Unplug the ice maker before touching internal components.
- Empty the ice basket: Remove all ice from the storage basket and the evaporator area. Overfilled baskets can trigger E2.
- Clean the sensor window: On many Salter models, the ice full sensor is an infrared pair near the top of the ice basket area. Wipe both sides of the sensor windows with a soft, dry cloth to remove condensation, frost, or mineral film.
- Check for obstructions: Ensure no ice cubes are stuck in front of the sensor or wedged under the sensor bracket.
- Reseat connectors (if accessible): Remove the side or rear panel (if user-serviceable). Locate the small PCB for the ice full sensor and gently press the plug-in connector to ensure it is fully seated.
- Power cycle: Leave the unit unplugged for 5–10 minutes, then reconnect and start a new cycle to see if the error clears.
If E2 persists, the ice full sensor assembly or its control board may require replacement.