E5 error, compressor does not start or stops quickly, no cooling
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Unplug the ice maker before inspection. Do not attempt to open the sealed refrigeration system.
- Ventilation check: Ensure there is at least 10–15 cm clearance around all sides of the Salter ice maker. Blocked vents cause overheating and E5.
- Clean condenser: Use a soft brush or vacuum to remove dust from the condenser coil and fan area at the back or side of the unit.
- Cool-down period: If the unit has been running continuously, unplug it and allow it to cool for 30–60 minutes, then restart.
- Stable power: Plug the unit directly into a wall socket (no extension leads or multi-way adaptors) to ensure proper voltage.
If E5 recurs immediately and the compressor does not run, the start relay or overload protector on the compressor may be faulty and should be replaced by a qualified technician.