E13
Scotsman
Discharge Temperature Sensor Fault
Display shows 'E13' and ice production stops
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Discharge thermistor open or short, sensor not attached to discharge line, wiring damage, control board sensor circuit failure
How to Fix / Troubleshooting
Safety: Disconnect power. The discharge line can be very hot; allow it to cool before touching.
- Locate discharge sensor: Find the thermistor clipped to the compressor discharge line.
- Check attachment: Ensure the sensor is firmly clamped to the line and not hanging loose.
- Inspect wiring: Look for burned, brittle, or cut wires near the hot discharge area.
- Test resistance: Measure sensor resistance and compare to specifications. Replace if open, shorted, or out of range.
- Control board: If the sensor and wiring are good, the control board may be at fault.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Discharge Thermistor
Check Price on Amazon