E5
Scotsman High Discharge Temperature or Refrigeration System Overheat

Display shows 'E5' and ice production stops

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty condenser coil, failed condenser fan motor, high ambient temperature, refrigerant overcharge or restriction, discharge temperature sensor fault

How to Fix / Troubleshooting

Safety: Disconnect power. Components near the compressor and discharge line can be very hot.

  • Clean condenser: Thoroughly clean the condenser coil with a brush and vacuum. Ensure nothing blocks airflow around the unit.
  • Check condenser fan: Verify the fan blade spins freely and the motor runs when the compressor is on. Replace the condenser fan motor if it does not run.
  • Verify installation: Ensure the unit has adequate clearance per Scotsman’s installation manual and is not installed in a confined, unventilated space.
  • Inspect discharge sensor: If equipped with a discharge line thermistor, check that it is properly attached and not damaged. Test resistance and replace if out of spec.
  • Refrigeration issues: If the code persists after cleaning and fan repair, a refrigeration problem (overcharge, restriction, non-condensables) may exist and must be addressed by a certified technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.