E8
Scotsman Low Water Safety or Water System Fault

Display shows 'E8' and unit will not start

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

No water supply, clogged water inlet screen, failed water inlet valve, low water pressure, water level sensor fault

How to Fix / Troubleshooting

Safety: Turn off power and close the water supply valve before disconnecting any water lines.

  • Check water supply: Verify the supply valve is open and there is adequate water pressure. Ensure the supply line is not kinked.
  • Clean inlet screen: Remove the water inlet line at the valve and clean the inlet screen of debris.
  • Inspect water level sensor: On reservoir-type Scotsman units, check the water level probe or float for scale buildup. Clean with a soft brush and descaler.
  • Test water inlet valve: During fill, the valve should energize. A technician can check for 120V/230V at the valve and measure coil resistance. Replace if not opening.
  • Reset and test: Restore water and power, then observe a fill cycle to confirm proper operation.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Inlet Valve
Check Price on Amazon

We may earn a commission from links on this page.