Scotsman
Reduced Ice Production
Unit makes ice but production is very low compared to rating
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty condenser coil, high ambient temperature, scale buildup on evaporator, low water flow, partially restricted refrigerant system
How to Fix / Troubleshooting
Safety: Disconnect power and water before cleaning.
- Clean condenser: Brush and vacuum the condenser coil. Ensure good airflow around the unit.
- Descale evaporator: Follow Scotsman’s descaling procedure to remove mineral buildup from the evaporator and water system.
- Check water filter: Replace clogged external water filters and ensure adequate water pressure.
- Verify ambient conditions: Confirm the room temperature and water temperature are within Scotsman’s specified range.
- If performance remains poor: A technician should check refrigerant pressures and system performance for restrictions or low charge.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Condenser Coil
Check Price on Amazon