Possible Causes

Dirty condenser coil, high ambient temperature, scale buildup on evaporator, low water flow, partially restricted refrigerant system

How to Fix / Troubleshooting

Safety: Disconnect power and water before cleaning.

  • Clean condenser: Brush and vacuum the condenser coil. Ensure good airflow around the unit.
  • Descale evaporator: Follow Scotsman’s descaling procedure to remove mineral buildup from the evaporator and water system.
  • Check water filter: Replace clogged external water filters and ensure adequate water pressure.
  • Verify ambient conditions: Confirm the room temperature and water temperature are within Scotsman’s specified range.
  • If performance remains poor: A technician should check refrigerant pressures and system performance for restrictions or low charge.