Possible Causes
Overheating causing high pressure trips, faulty control board, unstable power supply, defective thermostat or sensor
How to Fix / Troubleshooting
Safety: Turn off power before inspecting internal components.
- Clean condenser and ensure airflow: Overheating can cause safety switches to trip and reset.
- Check sensors: Inspect thermistors and bin controls for loose connections causing intermittent signals.
- Monitor power: Verify stable voltage at the unit. Fluctuations can cause control resets.
- Control board: If mechanical and electrical issues are ruled out, the control board may be malfunctioning and require replacement.