SMAD Airlock or Blockage in Water Circuit

Water pump runs but no water reaches the evaporator.

Advertisements

Possible Causes

Air trapped in pump, kinked water line to evaporator, clogged inlet screen on pump, scaled spray bar

How to Fix / Troubleshooting

Safety: Unplug the unit and drain water before disconnecting hoses.

Steps:

  • Bleed air: Refill the reservoir and tilt the unit slightly to help air escape from the pump. Restart and listen for a steady water flow.
  • Inspect hoses: Check the hose from the pump to the evaporator for kinks or pinches. Straighten or reroute as needed.
  • Clean inlet screen: Remove the pump and clean any mesh screen or filter at its inlet.
  • Clean spray bar: Remove and descale the water distribution bar above the evaporator.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Circulation Water Pump / Water Hose to Evaporator
Check Price on Amazon