SPT
User Interface / Keypad Failure
Buttons on the control panel do not respond or respond intermittently.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Moisture ingress into control panel, Worn membrane keypad, Loose ribbon cable between keypad and control board, Failed display/control PCB
How to Fix / Troubleshooting
Safety first: Unplug the unit before opening the control panel.
- Dry the panel: If the panel is damp, allow it to dry completely. Do not spray cleaners directly on the panel.
- Inspect ribbon cable: Remove the front panel and reseat the ribbon cable connecting the keypad to the control board.
- Check for corrosion: Look for signs of moisture damage on the keypad and board. Clean light corrosion with isopropyl alcohol and a soft brush.
- Replace keypad or display board: If buttons remain unresponsive, replace the membrane keypad or the entire display/control board assembly as designed for your SPT model.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Control Panel Keypad
Check Price on Amazon