E8
SPT Control Board Communication / Internal Fault

SPT ice maker shows E8; unit may power on but no functions respond or cycle will not start.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted control board firmware, Failed control PCB, Loose display-to-main-board harness, Power surge damage

How to Fix / Troubleshooting

Safety first: Disconnect power before opening the control panel.

  • Hard reset: Unplug the unit for at least 10 minutes to allow capacitors to discharge. Plug back in and test.
  • Inspect control connections: Remove the front or top panel to access the control board and display board. Reseat all ribbon cables and harness connectors.
  • Check for burn marks: Look for obvious damage on the PCB such as burnt components or discoloration. If present, the board must be replaced.
  • Surge protection: If the error occurred after a power outage or surge, consider using a surge protector once the board is replaced.
  • Replace control board: If E8 persists after reseating connectors, replace the main control PCB with the correct SPT part number. Transfer any wiring one connector at a time to avoid miswiring.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon