E9
SPT Condenser Fan / Airflow Fault

Display shows E9; ice maker may start but shuts down quickly; fan may not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed condenser fan motor, Obstructed fan blades, Fan wiring harness issue, Control board fan driver failure

How to Fix / Troubleshooting

Safety first: Unplug the unit before accessing the rear or bottom panel.

  • Inspect fan area: Remove the rear or bottom cover to access the condenser fan. Check for dust buildup, plastic wrap, or other debris blocking the blades.
  • Spin test: Gently spin the fan blades by hand. If stiff or seized, the motor is likely bad and should be replaced.
  • Check wiring: Ensure the fan connector is fully seated on the control board and that wires are not damaged.
  • Test after cleaning: Clean the fan and condenser coil, reassemble, and power on. If the fan still does not run and E9 returns, replace the fan motor.
  • Board check: If a known-good fan motor does not run, the control board may not be sending power and will need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.