SPT Ice Level Detection Failure (No Shutoff)

Unit continuously runs but produces too much ice and overflows the basket.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Ice full sensor not detecting ice, Sensor blocked in open position, Disconnected sensor wiring, Failed control board input

How to Fix / Troubleshooting

Safety first: Unplug the unit before working near sensors.

  • Clean and inspect sensor: Wipe the ice full sensor lenses and ensure they are not covered by frost or mineral deposits.
  • Check wiring: Verify the sensor harness is connected securely to the control board.
  • Test sensor: With the cover off (if safe), block the sensor path with a non-reflective object and see if the unit responds by stopping ice production. If not, the sensor or board is faulty.
  • Replace sensor or board: Install a new ice full sensor assembly first. If the issue persists, the main control board may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ice Full Sensor Assembly