SPT Compressor Start Circuit Failure

Unit displays lights but the compressor never starts; only fan and pump run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective compressor start relay, Open overload protector, Loose compressor terminals, Failed compressor winding

How to Fix / Troubleshooting

Safety first: Unplug the unit before accessing the compressor. Capacitors can hold charge; discharge safely if present.

  • Inspect terminals: Remove the compressor cover and ensure all terminals are firmly connected.
  • Check start relay: Remove and test or replace the start relay if it shows signs of burning or rattles when shaken.
  • Overload protector: Test continuity through the overload device; replace if open when cool.
  • If compressor still does not start: The compressor itself may be failed and will require replacement by a licensed refrigeration technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Overload and Start Relay
Check Price on Amazon

We may earn a commission from links on this page.