Ice maker displays EC90 or service code 90 and will not run. Control appears unresponsive or stuck in error.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Disconnect power at the breaker before accessing the control compartment.
Steps to address EC90:
- 1. Power cycle: Turn off power for at least 10 minutes to allow the control to fully discharge. Restore power and check if the error clears.
- 2. Inspect control connections: Remove the front grille or control cover to access the main control board. Verify all harness connectors are fully seated. Gently unplug and replug each connector to clean contacts.
- 3. Check for visible damage: Look for burn marks, swollen components, or corrosion on the control board. Any visible damage usually means the board must be replaced.
- 4. Verify supply voltage: Use a multimeter (if qualified) to confirm correct line voltage at the ice maker's terminal block. Incorrect voltage can cause control faults and must be corrected by an electrician.
- 5. Replace control board: If EC90 persists and wiring and voltage are correct, the control board is likely defective. Replace it with an OEM Sub-Zero board, transferring any jumpers or programming plugs as specified in the service instructions.
Warning: Control board replacement involves exposure to live circuits if power is not fully disconnected. If you are not experienced with electrical work, contact a professional.
Repair Difficulty
Required Part
We may earn a commission from links on this page.